HPHT IFT (Static/Dynamic) and Contact Angle Measurement for Oil-Water, Oil-Gas and Gas-Water Systems
Interfacial tension and contact angle measurements are necessary for understanding of any oil and gas recovery process that includes fluid-fluid and rock-fluid interactions, respectively. EOR, acidizing, and fracturing rock-fluid systems all require at least one of these measurements in order to have a compatible fluid system designed.
TORP is well equipped to conduct laboratory testing under reservoir conditions for both static and dynamic IFT and contact angle measurements.
- Oil-water, oil-gas and gas-water IFT measurements
- Dynamic IFT measurements to understand interfacial elasticity
- Oil-water, oil-gas and gas-water contact angle measurements
- Temperature: 77-400 °F
- Pressure: up to 10,000 psi